Fiber optic cables have provided a more optimal use of available underground conduit space because of its small cable diameter and the much higher. Construction 4 general 61 additional cable variations 63 i additional electrical data 64 ii tests on power and control cables iii general information datasheets pvc insulated low voltage cables 70. Maryland task force to study moving overhead utility lines underground md 2003 the maryland task force was created by law in 2002 and charged with facilitating converting the overhead lines to underground lines. In terms of reliability, capability, cost, construction impacts and land use, overhead lines do have advantages when compared to underground cables. For the purpose, either threecore cable or three single core cables may be used. Figure below shows the construction of 3 core cable. Trees replace wires, and trees dont have to be trimmed. However, the latter method of classification of underground cables is generally preferred, according to which cables can be divided into the following groups. An introduction to high voltage direct current hvdc. See here for the magnetic fields produced by underground cables and. Underground electric transmission lines wisconsin psc. An underground cable consists of conductor, insulation, sheath, bedding, armour and serving. This article is about construction of underground cables. Code of practice for avoiding danger from underground.
Cable construction introduction this article gives a brief exposition on the construction of typical low voltage, medium high voltage and instrumentation cables. Increasingly cables are being seen as the lowest cost solution for reliable delivery of power. An underground cable essentially consists of one or more conductors covered with suitable insulation and surrounded by a protecting cover. In practice, underground cables are generally required to deliver 3phase power. This is known as direct burial, and if you do this, the uf cable must be at least 24 inches below the surface of the ground, to minimize the chance. These are used when the voltage requirement exceeds 66kv and solid cables cant be used. Undergroundsubmarine cable protection using a negativesequence directional comparison scheme free download abstract protective relaying requirements for underground and submarine cables are. An underground cable when used at high voltage consists of one or more central conductor core of stranded aluminium. As these cables are not exposed to the air atmosphere, this makes the ug cabling system less susceptible to outages due to various atmospheric conditions like high wind, storm, thunder storms, heavy snow or ice storms etc. Technical specification for underground power cables and accessories for nominal system. For underground cables, a nylon jacket can be applied for termite protection, although sometimes a phosphor bronze tape is used. The other utilities must maintain clearances as outlined in the nesc or by mutual agreement. Fortisbc specification for installation of underground conduit systems revision date. Underground power cables high voltage underground cables 2 2 circuits 3000m 3x1x2000mm2 e.
Underground cables are usually employed to deliver 3 phase power. Underground cable and ducts are part of the underground conduit system. Jun 02, 2018 classification of underground cables may be in two ways according to. Underground power cables and accessories for nominal system voltages of 66kv and 2 kv jts040110. Telecommunication conduits are made from various materials and buried directly into the soil or encased in concrete.
Innovative underground technology and engineering for sustainable development. It helps to predict when and what kind of repairs might be needed in the future, or if faulty sections need immediate replacement. This paper analyzes the application of directional comparison schemes to protect two 34. Underground cables april 2018ver2mh the width of the working strip is dependent upon the the voltage of the underground cable, the number of cables and how many trenches are required. Commission, which found that the cost to underground the entire distribution system to be prohibitive. Construction of underground cables electrical edition. Commscope cables meet or exceed all telcordia gr409core and ansiicea 696 requirements, as well as gr20core requirements for crush resistance, impact resistance, flexing and twistbend. Cable riser insulators cable support blocks 2212 cable support blocks cable support blocks support underground cables in manholes, vaults, and conduit. If the municipality passes ordinances making underground. A cable may have one or more conductor depending upon the type of service. Underground technology development and engineering advances are spurred by underground construction requirements throughout the world parriaux et al.
However, a significant benefit of undergrounding cables is the reduction in visual impact. The information from this project contributes to energy research and development divisions energy systems integration program. Underground commercial distribution ucd installation and. Transmission cables are often 35in 75125mm in diameter and may be installed directly buried or in, typically, 68in 152203mm plastic conduits with commercial installations up to 500kv.
The challenge with the existing methods used for locating faults in underground cables is the inaccuracy in calculating the distance where the fault is located and the low durability of such. Although several types of underground cables are available, the. Construction of underground cables studyelectrical. Any underground cables which are damaged during installation should be immediately repaired with equal quality material. So, this paper shows the details of different kind of cables and one is suitable for the long transmission line and. The primary function of the vault is for splicing the cables during construction and for permanent. If it is done in conjunction with retiring old overhead lines. The material used in the manufacture of cable should be such that there is complete chemical and physical stability throughout. This chapter deals with many special features of underground power cables. Power grids underground medium voltage prysmian group. Construction 4 general 61 additional cable variations 63 i additional electrical data 64 ii tests on power and control cables iii general information datasheets pvc insulated low voltage cables 70 c 7 yyfl, unarmoured 2, 3, 4 and 5cores 8 multicores 12 yyryfl, armoured 2, 3, 4 and 5cores 14 multicores 18. Code of practice for avoiding danger from underground services 2 9. Overhead or underground a comparison legislative services. If it is done in coordination with other projects like road repair.
Fault analysis in underground cables is the final report for the underground cables project, contract number 500. Classification of underground cables construction of cables. Vaults vaults are large concrete boxes buried at regular intervals along the underground construction route. It may be increased at certain points, for example road, rail, river and canal crossings, to accommodate the more complex construction processes at these locations. Pdf design and implementation of underground cable fault. At ground level, instead of poles every 150 ft many having one or more. Conditionbased maintenance this checks underground power transmission cables and aboveground grid fixtures like joints and terminations that have already experienced partial damage. An underground cable essentially consists of one or more conductors covered with suitable insulation and surrounded by some protective layer. The world leader in the energy and telecom cables and systems industry product finder discover products and solutions.
G eotechnologies and related science and engineering fields make it possible to use underground space to support. Introduction increasingly, utilities, developers and power producers seeking to build new power transmission systems are required to at least consider underground cables as an alternative to overhead lines. Technical specification for underground power cables and. See here for the magnetic fields produced by underground cables and specifically the fields produced by these three different types. Laying uf underground feeder cable directly into the ground. Read underground engineering for sustainable urban.
Threeconductor cables are available up to 8kv, but the vast majority of underground extruded circuits use singleconductor cables. Further, the vertical runs where the cable descends into the ground at the house side. The structure of medium voltage cables with extruded insulation will always involve the following items. Beyond that, insulation required for the cable is too much. This is known as direct burial, and if you do this, the uf cable must be at least 24 inches below the surface of the ground, to minimize the chance of the cable being pierced by routine shoveling. Vaults vaults are large concrete boxes buried at regular intervals. The focus is on thermoplastic and thermosetting insulated cables, however the construction of other cables are similar. Underground submarine cable protection using a negativesequence directional comparison scheme free download abstract protective relaying requirements for underground and submarine cables are different from those for overhead lines.
High voltage direct current hvdc underground cables have been in commercial use since the 1950s. The highvoltage underground cables used on the national grid system can be one of three types. Used only in particular applications with specialised construction, these underground cables can be further divided as htype and s. Underground installation of optic fiber cable placing. Underground cable introduction and construction electrical. For underground cables less than 345 kv, the connection from overhead to underground lines require the construction of a transition structure, also known as a. Maryland task force to study moving overhead utility lines underground md 2003 the maryland. Introduction since the loads having the trends towards growing density. Underground power cable, distribution cable, overhead. Classification of underground cables may be in two ways according to.
For higher voltages, 3 cored constructions become too bulky, and hence, even with some limitations we employ single cored cables. Underground cables have different technical requirements than overhead lines and have different environmental impacts. It has been in service for more than 40 years, has proven highly reliable and can be provided by european. Construction details of single core xlpe insulated armoured pvc sheath underground cable the figure shows a circular compacted stranded copper or aluminium conductor, xlpe insulated, with copper tape screened and covered with extruded pvc bedding, aluminium wire armored and pvc outer sheath. At ground level, instead of poles every 150 ft many having one or more guy wires urban construction has no obstacles, and urdstyle construction has just padmounted transformers spaced much less frequently. Mafijur rahman electrical and electronic engineer professional associates limited. Ppt underground cables powerpoint presentation free to. This recognition is seen in the increasing use of cables within utilities.
Specification for installation of underground conduit systems. Understanding underground electric transmission cables. Under ground cables presention linkedin slideshare. As these cables are not exposed to the air atmosphere, this makes the ug cabling system less susceptible to outages. It is impossible to cover all the various conditions that may arise during an. The discussion is focused on transmission cables but also has relevance for distribution cable applications.
Due to their different physical, environmental, and construction needs, underground transmission generally costs more and may be more complicated to construct than overhead lines. Premise cables these cables are designed to handle the stresses of indoor applications. Underground circuits get rid of all that mess, with no visual impacts in the air. In overhead power lines, a structure based network is used to transmit. Although the cable structure had a proven track record, the unexperienced.